Tags give the ability to mark specific points in history as being important
-
-
-
V3.4.7
d897ca65 · ·New event import functionality: You can now either load new event markers from a text file and (1) delete the existing ones, (2) keep the existing ones, (3) recode the existing ones.
-
V3.4.6c
a945c4e5 · ·Import of Biotrace UK format now supported; Butterworth filter function extended and included in batch-analysis. CDA-PhasicMax score added (again) to event-related activation measures. Minor debugging.
-
V3.4.5
c34cffa3 · ·EDA_Results script allows saving aggregated EDA scores for all analyzed files of an experiment (see help EDA_Results). leda2.analysis variable provides access to onsets, peak times and amplitudes of all reconvolved SCRs and phasic driver peaks (after CDA). Plus minor debugging.
-
V3.4.4
d38928f1 · ·More flexible import of events with time and optional marker info. Potential conflict for downsample-function with Signal Processing TB removed. Minor bug-fixes.
-
V3.4.3
1fc9dbbd · ·Ledalab now imports data from text-files with variable format (Text Type 3; manual definition); Text Type 2 was changed to the standard format [SC (Marker)].
-
V3.4.2
235ce333 · ·Export of SCR-List now available in batch-mode; export of SCR-list no longer requires events.
-
V3.4.1
9a079260 · ·A tool was added which allows to plot event-related data per conditions (contributed by Christoph Huber-Huber) - see Tools. This is great way to visualize the effect of your experimental conditions on the EDA data (phasic driver and phasic data after CDA). Further minor debugging and optimization.
-
V3.4.0
40713a55 · ·Analysis and export of standard event-related activation scores (number of SCRs, latency, amplitude-sum) now also available for CDA. Export of SCR-List (txt, xls, mat) included. More consistent labelling of scores.
-
-
-
V3.3.2
538383ec · ·Ledalab was patched to ensure Linux-compatibility (contributed by Vincent Emanuele).
-
V3.3.1
07658558 · ·Direct import of Biopac-files now supported (i.e., the workaround via BioSig is no longer required). Single and multiple event-channels are supported (see documentation).
-
-
V3.2.9
918bbf36 · ·CDA-parameter SCR added (see documentation). Vision Analyzer Import more robust. Writing of log-files more informative and more robust.
-
-
V3.2.7
77d2ea6a · ·Batch-mode now includes smoothing; batch-options for analysis-method changed (see online docu). Event-related analysis now also exports to Excel-files; mind that the variable-structure of the Matlab-export slightly changed. Minor debugging. [unstable]
-
V3.2.6
2b132eeb · ·Import functionality for Biopac data via BioSig toolbox (see http://biosig.sourceforge.net/). Initial values for optimization now based on empirical results in reference publications.
-